<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-21 20-30-11
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 55 dBuV VOLTAGE
Pilot RDS Phase Difference
7.2 kHz 3.8 kHz -74 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 74 kHz 10138 48,3330
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
7,7 dBr 8,11 dBr 8,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 20:30, 21.03.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (55 dBuV) Max at: 74 kHz MIN: 11 kHz % above 76 kHz: 48,3330 Acquired: 2025/03/21 20:29:08 Total samples: 10138 Equivalent time: 0:08:26 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 8,5 dBr MIN: 7,7 dBr AVE: 8,11 dBr % above 10,2 dBr: 0,0 Last value: 8,2 dBr (2025/03/21 20:29:08) Station: 96.90 MHz, signal: 4/5 (56 dBuV) 20:22 20:23 20:24 20:25 20:26 20:27 20:28 20:29 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality